AE-GLC-SX-MM

SFP Module

It is a compact and efficient 1G SFP transceiver designed for high-speed data transmission over multimode fiber (MMF). It offers a reliable and cost-effective solution for various networking applications, including high-speed storage area networks, computer cluster cross-connects, and custom high-speed data pipes.

Specification

Absolute Maximum Ratings
Parameter Symbol Min. Max. Unit Notes
Storage Temperature Ts -40 +85 °C
Supply Voltage Vcc3 0 3.6 V
Relative Humidity RH 5 +85 % Note
Rx Input Average Power Pmax - +1.5 dBm
Recommended Operating Conditions
Parameter Symbol Min. Typical Max. Unit
Operating Case Temperature Tc 0 25 +70 °C
Power Supply Voltage Vcc3 3.13 3.3 3.47 V
ICC3 - - 300 mA
Power Dissipation PD - - 1.0 W
Data Rate 1.25 Gbps
Transmitter Operating Characteristic Optical, Electrical
Parameter Symbol Min. Typical Max. Unit Note
Centre Wavelength λc 800 850 900 nm
Spectral Width Δλ 4 nm DFB
Average Optical Power Pavg -9 - -3 dBm
Laser Off Power Poff - - -40 dBm
Extinction Ratio ER 8.2 - - dB
Operating Data Rate - 1.25 - Gbps
Optical Eye Mask Complies with IEEE802.3z eye masks when filtered
Tx Input Diff. Voltage VI 500 - 2400 mV
Tx Fault VoL -0.3 - 0.4 V
VoH 2.4 - VCC+0.3
Receiver Operating Characteristic-Optical, Electrical
Parameter Symbol Min. Typ. Max. Unit Note
Center Wavelength λr 800 900 nm
Receive Sensitivity In Average Power Psen - - -18 dBm
Los Assert LosA -35 - - dBm
Los Dessert LosD - - -20 dBm
Los Hysteresis LosH 0.5 - -6 dB
Overload Pin - - -3 dBm
Rx Output Diff Voltage Vo 370 2000 mV
Operating Data Rate - 1.25 - Gbps
Digital Diagnostic Functions
Parameter Symbol Min. Max. Unit Note
Temperature monitor absolute error DMI_Temp -3 3 C Over operating temp
Laser power monitor absolute error DMI_TX -3 3 dB
RX power monitor absolute error DMI_RX -3 3 dB
Supply voltage monitor absolute error DMI_VCC -3% +-3% V
Bias current monitor absolute error DMI_lbias -10% 10% mA
Control and Status 1/0 Timing Characteristics
Parameter Symbol Min. Max. Unit Note
TX Disable Assert Time t_off - 100 μs Note1
TX Disable Negate Time t_on - 2 ms Note2
Time to initialize including reset of TX_Fault t_init - 300 ms Note3
TX Fault Assert Time t fault_on - 1 ms Note4
TX Fault Reset Time t_reset 10 - μs Note5
LOS Assert Time t_loss_on - 100 μs Note6
LOS Deassert Time t_loss_off - 100 μs Note7

Documentation

Datasheet
Certificate
Test Report

Get in Touch for the Best Solutions

Welcome Form AEconnect
AE CONNECT INDIA PVT LTD

Product Inquiry

Product Inquiry